Getting Started with the NI LabVIEW
Embedded Module for ADI Blackfin
Processors
Version 2.0
The NI LabVIEW Embedded Module for ADI Blackfin Processors is a
comprehensive graphical development environment for embedded design.
Jointly developed by Analog Devices and National Instruments, this
module seamlessly integrates the LabVIEW development environment
and Blackfin embedded processors.
This module builds on NI LabVIEW Embedded technology, which
facilitates dataflow graphical programming for embedded systems and
includes hundreds of analysis and signal processing functions, integrated
I/O, and an interactive debugging interface. With the Embedded Module
for Blackfin Processors, you can enable cache, optimize linking, and view
live front panel updates using JTAG, serial, or TCP/IP, as well as use
VisualDSP++ compiler options through LabVIEW. The Embedded Module
for Blackfin Processors includes the LabVIEW C Code Generator, which
generates C code from the LabVIEW block diagram.
development times, and still deliver a high performance embedded
Upgrading to the Embedded Module for Blackfin Processors 2.0 ......... 6
Embedded Project Manager............................................................. 6
Upgrading Blackfin VIs and Embedded Projects............................ 6
Migrating Custom Linker Description Files.................................... 8
Tutorial.................................................................................................... 9
Creating the LabVIEW Project........................................................ 9
After you install LabVIEW, refer to the LabVIEW Upgrade Notes,
available by selecting Start»All Programs»National Instruments»
LabVIEW»LabVIEW Manuals and opening LV_Upgrade_Notes.pdf,
for more information about new features in LabVIEW 8.2. Refer to the
LabVIEW 8.2.1 Readme for Windows, available by selecting Start»
All Programs»National Instruments»LabVIEW»Readme and opening
readme.htmlfor information about features and changes in
LabVIEW 8.2.1.
System Requirements
The Embedded Module for Blackfin Processors has the following
requirements:
•
•
•
•
A desktop computer with Windows Vista/XP/2000
Analog Devices VisualDSP++ 4.5 (included)
LabVIEW 8.2.1 with embedded support (included)
One of the following EZ-KITs:
–
EZ-KIT Lite for Analog Devices ADSP-BF537 Blackfin
Processor (included)
–
–
EZ-KIT Lite for Analog Devices ADSP-BF533 (not included)
EZ-KIT Lite for Analog Devices ADSP-BF538 (not included)
the info code relnote82to access the LabVIEW Release Notes for more
information about LabVIEW development system requirements.
Installing the Embedded Module for BlackfinProcessors
If you have LabVIEW 8.2 installed, you can install LabVIEW 8.2.1
without first uninstalling LabVIEW 8.2. If you do not have LabVIEW 8.2
installed, you can install LabVIEW 8.2.1 without first installing
LabVIEW 8.2.
Note Because LabVIEW installs 8.2.1 over 8.2, you cannot have both LabVIEW 8.2 and
8.2.1 installed simultaneously.
Complete the following steps to install the Embedded Module for Blackfin
Processors.
1. Log in as an administrator or as a user with administrator privileges.
2. Insert the Analog Devices VisualDSP++ 4.5 installation CD and
follow the instructions on the screen to install VisualDSP++ 4.5.
© National Instruments Corporation
3
Embedded Module for Blackfin Processors
Tip If the installer does not automatically begin, double-click VisualDSP++4.5.exeon
the CD to begin installation.
3. After you finish installing VisualDSP++, select Start»All Programs»
Analog Devices»VisualDSP++ 4.5»Maintain this installation.
4. Select Apply a downloaded Update and click the Next button in the
VisualDSP++ 4.5 - Setup wizard.
5. Open the .vdufile on the Analog Devices VisualDSP++ 4.5
installation CD, click the Next button, and follow the rest of the
instructions to install the VisualDSP++ update.
6. Insert the LabVIEW 8.2.1 with Embedded Support CD and select to
install the software.
Note LabVIEW 8.2.1 with embedded support is a special edition of LabVIEW 8.2.1.
7. Follow the activation instructions that appear on the screen.
You also can use the NI License Manager, available by selecting
Start»All Programs»National Instruments»NI License Manager,
to activate National Instruments products. Refer to the National
Instruments License Manager Help, available by selecting Help»
Contents in the NI License Manager, for more information about
activating NI products.
8. Restart the computer when the installer prompts you and log on as an
administrator or as a user with administrator privileges.
9. Insert the LabVIEW Embedded Module for Blackfin Processors 2.0
installation CD and follow the instructions on the screen.
Tip If the installer does not automatically begin, double-click setup.exeon the CD to
begin installation.
10. Follow the activation instructions that appear on the screen.
Embedded Module for Blackfin Processors
4
ni.com
Installing the EZ-KIT Lite or Emulator
Caution Be careful when removing the board from the package and handling the board to
The EZ-KIT Lite or USB-based ICE board is designed to run as a
stand-alone unit. You do not have to open the computer case.
Note You must install VisualDSP++ before you can install the Blackfin target. Refer to
the Installing the Embedded Module for Blackfin Processors section for information about
installing VisualDSP++.
Complete the following steps to install the EZ-KIT Lite or USB-based ICE.
1. Plug the power supply for the board into a surge-protected outlet.
Connect the USB assembly for the board to the USB port on the host
computer using the provided USB cable.
Figure 1 shows the location of the A/C adaptor and USB port on the
Blackfin target. Refer to the ADSP-BF537 EZ-KIT Lite Evaluation
System Manual in the EZ-KIT box for more detailed information about
the ADSP-BF537 EZ-KIT Lite hardware.
A/C Adaptor
USB to Host PC
ANALOG
DEVICES
Figure 1. Locating the A/C Adaptor and USB Port on the Blackfin Target
© National Instruments Corporation
5
Embedded Module for Blackfin Processors
On the board, the power LED illuminates, and you might see other
visible activity, such as blinking LEDs. The connection activates the
Windows Found New Hardware Wizard.
2. Follow the instructions on the screen to install the software
automatically. A Windows message notifies you when the new device
is ready for use and the hardware installation is complete.
3. Verify that the USB monitor LED is lit. The LED is in close proximity
to the USB connector. The lit LED signifies that the board is
communicating properly with the host computer and is ready to run.
Refer to the ADSP-BF537 EZ-KIT Lite Evaluation System Manual in
the EZ-KIT box for more detailed information about the USB monitor
LED.
4. For a USB-based ICE, attach the JTAG cable to the emulation target.
Refer to the emulator documentation for more information about
USB-based ICE.
Upgrading to the Embedded Module for Blackfin
Processors 2.0
This section describes upgrade and compatibility issues for the Embedded
The Embedded Module for Blackfin Processors no longer supports the
Embedded Project Manager. Use the Project Explorer window instead.
Refer to the Creating the LabVIEW Project section for information about
using the Project Explorer window. Refer to the Upgrading Blackfin VIs
and Embedded Projects section for information about converting
embedded project (.lep) files.
Upgrading Blackfin VIs and Embedded Projects
If you created Blackfin VIs using the Embedded Module for Blackfin
Processors 1.0, you must create projects and update the VIs for use with
LabVIEW 8.2.1 and the Embedded Module for Blackfin Processors 2.0.
Caution National Instruments recommends you back up your files before you
begin updating your Blackfin VIs for use with the Embedded Module for Blackfin
Processors 2.0. The Embedded Module for Blackfin Processors 1.0 cannot open VIs
you save in version 2.0.
The Embedded Module for Blackfin Processors includes a utility to
help you convert LabVIEW 7.1 embedded project (.lep) files to
Embedded Module for Blackfin Processors
6
ni.com
LabVIEW 8.2.1 project (.lvproj) files. Complete the following steps to
update embedded project files for use with LabVIEW 8.2.1 and the
Embedded Module for Blackfin Processors 2.0.
1. Launch LabVIEW 8.2.1.
2. Select File»Open in the Getting Started window and navigate to the
labview\Targets\ADI\Embedded\vdk\utils\Blackfin LEP
Converter\directory.
3. Select Blackfin_LEP_Converter.viand click the OK button to
run the Blackfin LEP converter utility.
4. Complete the following steps to add the LEP file you want to import to
the LabVIEW Embedded Project (*.lep) Files list.
a. Click the Add button below the LabVIEW Embedded Project
(*.lep) Files list. The Select an Embedded Project to Add dialog
box appears.
b. Navigate to the location of the LEP file you want to import.
c. Click the Add button. LabVIEW adds the LEP file and all the VIs
associated with the LEP file to the Blackfin LEP converter utility.
You can see only the LEP file in the LabVIEW Embedded
Project (*.lep) Files list.
5. Click the Continue button. LabVIEW prompts you to specify the
location and name of the new project.
6. The Import Status dialog box appears. When LabVIEW finishes
importing the 1.0 files, the Project Explorer window appears with
the Blackfin target and VIs.
a. Right-click the Blackfin target in the Project Explorer window
and select Configure Target from the shortcut menu.
b. Verify the settings in the VisualDSP++ Target Configuration
dialog box and click the OK button. Refer to the Configuring the
Target and Debugging Options section for information about
configuring the Blackfin target.
the Project Explorer window and select Properties from the
shortcut menu to open the Build Specifications Properties dialog
box.
d. Verify the settings in the Application Information and Source
Files categories and click the OK button. Refer to the Creating the
ADSP-BF537 Build Specification section for information about
editing a build specification.
© National Instruments Corporation
7
Embedded Module for Blackfin Processors
8. Select File»Save in the Project Explorer window to save the project.
LabVIEW saves a copy of all the VIs for the project in the same folder
as the .lvprojfile.
Refer to the Building, Downloading, and Running a Blackfin Application
section for information about building a Blackfin VI into a Blackfin
application and running the application on the target.
Migrating Custom Linker Description Files
If you used the Embedded Module for Blackfin Processors 1.0 to move
to custom hardware, you modified the Linker Description File (LDF) to
match the hardware layout of the custom hardware memory layout. The
.ldffile defines the system to the VisualDSP++ linker and specifies how
the linker creates executable code.
You must rewrite custom .ldffiles to use them with the Embedded Module
for Blackfin Processors 2.0 because the format of .ldffiles changed from
VisualDSP++ 4.0 to VisualDSP++ 4.5.
Refer to the Moving to Custom Hardware topic in the LabVIEW Help,
available by selecting Help»Search the LabVIEW Help in LabVIEW,
for information about modifying .ldffiles for a custom target.
Tip When searching for a specific topic in the LabVIEW Help from the Search tab, place
a checkmark in the Search titles only checkbox and enter the topic title in the Type in the
word(s) to search for textbox. This option limits the number of topics that the LabVIEW
Help finds so you can locate the topic more quickly.
Embedded Module for Blackfin Processors
8
ni.com
Tutorial
Use this tutorial to learn how to create a LabVIEW project and build, run,
and debug a Blackfin application.
Note You can create a project and Blackfin VI without connecting a Blackfin target to the
host computer. However, you must connect a Blackfin target to the host computer before
you can test a Blackfin application. Refer to the Installing the EZ-KIT Lite or Emulator
section for information about installing the Blackfin target.
Creating the LabVIEW Project
Use LabVIEW projects to group together LabVIEW files and
non-LabVIEW files, create build specifications for building a Blackfin VI
into a Blackfin application, and run the application on a Blackfin target.
You must use a project to build a Blackfin VI into a Blackfin application.
LabVIEW project files have a .lvprojfile extension. Project files contain
target-specific build options and other information necessary for the
LabVIEW C Code Generator to generate C code from the VIs.
Complete the following steps to launch LabVIEW and create a project with
an ADSP-BF537 target and a blank VI.
1. Launch LabVIEW.
2. Select Empty Project in the Getting Started window to open an
empty LabVIEW project as shown in Figure 2. LabVIEW creates
an empty project with a Windows target, shown in Figure 2 as
My Computer.
Figure 2. Targeting My Computer in the Project Explorer Window
© National Instruments Corporation
9
Embedded Module for Blackfin Processors
4. Expand the Embedded folder and select Analog Devices
ADSP-BF537 as shown in Figure 4.
Figure 4. Adding a New Device
5. Click the OK button to add the target to the project. The target appears
in the Project Explorer window as shown in Figure 5.
Figure 5. Adding the ADSP-BF537 to the Project Explorer Window
© National Instruments Corporation
11
Embedded Module for Blackfin Processors
automatically adds Dependencies and Build Specifications under the
target. SubVIs appear under Dependencies when you add a VI that
contains subVIs to a project. Build specifications you create for a
target in a project appear under Build Specifications in the Project
Explorer window. Refer to the Creating the ADSP-BF537 Build
Specification section for information about how to create a build
specification.
Figure 6. Expanding the Blackfin Target in the Project Explorer Window
7. Right-click the ADSP-BF537 target and select New»VI from the
shortcut menu. The new, untitled VI appears in the Project Explorer
window under the ADSP-BF537 target as shown in Figure 7.
Figure 7. Adding a New VI to the Project
The front panel and the block diagram of the new VI open. The front
panel, or user interface, appears with a gray background and includes
controls and indicators. The block diagram appears with a white
background and includes VIs, functions, and structures that control the
front panel objects.
Embedded Module for Blackfin Processors
12
ni.com
Creating the Front Panel
The front panel is the user interface for a VI. You can use the front panel as
This tutorial includes an LED indicator that lights if the input exceeds a
threshold value you define.
Complete the following steps to create the front panel.
1. Place the following controls on the block diagram as shown in
Figure 8:
•
•
•
Two numeric controls located on the Numeric palette.
One numeric indicator located on the Numeric palette.
One round LED located on the Boolean palette.
Tip If you cannot find the object you are looking for, click the Search button on the
Controls or Functions palette toolbar. Type the name of the object for which you want
to search. LabVIEW searches as you type and displays any matches in the search results
text box.
Figure 8. Creating the Front Panel
© National Instruments Corporation
13
Embedded Module for Blackfin Processors
2. Rename the controls by double-clicking the labels and entering new
names as shown in Figure 9.
•
•
•
•
Change one of the numeric controls to input.
Change the other numeric control to threshold.
Change the numeric indicator to output.
Change the round LED to threshold exceeded?.
Tip Double-click to select a single word in a label. Triple-click to select the entire label.
Figure 9. Changing the Labels
3. Change the numeric representation of the numeric controls and the
output numeric indicator to a 32-bit signed integer by right-clicking
each control and indicator and selecting Representation»I32 from the
shortcut menu.
Creating the Block Diagram
The block diagram is the source code for a VI and contains a pictorial
description or representation of an application. Wires carry data between
the objects, or nodes, on the block diagram. The controls and indicators you
added in the Creating the Front Panel section appear as terminals on the
block diagram.
Complete the following steps to create the block diagram.
1. Switch to the block diagram by clicking the block diagram if it is
visible or selecting Window»Show Block Diagram.
Tip You also can switch to the block diagram by pressing the <Ctrl-E> keys.
2. Select Help»Show Context Help to display the Context Help
window. The Context Help window displays basic information about
LabVIEW objects when you move the cursor over each object.
Tip You also can press the <Ctrl-H> keys to open and close the Context Help window.
Embedded Module for Blackfin Processors
14
ni.com
3. Create the block diagram as shown in Figure 10.
a. Place a While Loop located on the Structures palette around the
controls and indicator on the block diagram. While Loops repeat
the subdiagram inside it until the conditional terminal, which is an
input terminal, receives a particular Boolean value. Right-click the
conditional terminal, shown at left, in the lower right corner of the
While Loop and select Create Constant from the shortcut menu.
The default Boolean constant in the While Loop is FALSE.
b. Place a Multiply function located on the Numeric palette on the
block diagram inside the While Loop.
c. Wire the input control to the x input of the Multiply function.
d. Right-click the y input of the Multiply function and select
Create»Constant from the shortcut menu. Enter 2to multiply the
value of the input control by two.
e. Place a Greater? function located on the Comparison palette on
the block diagram.
f. Wire the x*y output of the Multiply function to the x input of the
Greater? function.
g. Wire the threshold control to the y input of the Greater? function.
h. Wire the x > y? output of the Greater? function to the threshold
exceeded indicator.
i. Wire the output indicator to the wire connecting the Multiply
function and the Greater? function.
j. Place a Wait Until Next ms Multiple function located on the Time,
Dialog, & Error palette inside the While Loop.
k. Right-click the millisecond multiple input and select
Create»Constant from the shortcut menu. Enter 100to wait
100 milliseconds.
Figure 10. Creating the Block Diagram
© National Instruments Corporation
15
Embedded Module for Blackfin Processors
4. Save the VI as Blackfin Tutorial.
Configuring the Target and Debugging Options
The target options you set tell LabVIEW how the Blackfin target is
connected to the host computer. The EZ-KIT Lite is connected to the host
computer through the USB port, which also is known as a debug agent.
Note You only have to configure the target once unless you change how you connect the
target to the host computer.
Complete the following steps to configure the target options.
1. Right-click Analog Devices ADSP-BF537 in the Project Explorer
window and select Configure Target from the shortcut menu to open
the VisualDSP++ Target Configuration dialog box. The current
version and location of VisualDSP++ in the Product name list and the
Location text box reference the version of VisualDSP++ on the host
computer. Correct the product name and location if necessary.
pull-down menu.
3. Select ADSP-BF537 EZ-KIT Lite via Debug Agent from the
Platform pull-down menu.
4. Select ADSP-BF537 from the Processor pull-down menu as shown in
Figure 11.
Figure 11. Configuring the Target Settings
Embedded Module for Blackfin Processors
16
ni.com
5. Click the Debug Options tab to configure the debug options you can
use while debugging a Blackfin application on the Blackfin target.
Tip Click the Help button to open the LabVIEW Help and read a description of each debug
setting.
6. Change the Front Panel/Probe Update Period (ms) to 100 by
moving the slider or typing 100in the numeric control under the slider
as shown in Figure 12. This setting configures how often the front
panel updates with data from the Blackfin application.
Figure 12. Configuring the Debugging Options
7. Click the OK button.
© National Instruments Corporation
17
Embedded Module for Blackfin Processors
Creating the ADSP-BF537 Build Specification
Build specifications tell the LabVIEW C Code Generator how to generate
the C code and build the Blackfin VI into a Blackfin application. You can
create the build specification when you create a project or wait until you are
ready to build the Blackfin VI into a Blackfin application.
You can have multiple build specifications for the same target. For example,
you might want one build specification that generates debugging
information and another build specification that does not generate this extra
information.
Complete the following steps to create a build specification.
1. Right-click Build Specifications under the ADSP-BF537 target and
2. LabVIEW prompts you to save the project. Click the Save button when
prompted and save the project as Blackfin Tutorial. The Build
Specification Properties dialog box opens.
3. (Optional) LabVIEW might prompt you to configure the target. Click
the Yes button and refer to the Building, Downloading, and Running a
Blackfin Application section for information about configuring the
target.
4. Select Debug in the Build Configuration section of the General
tab. The debug build configuration does not apply any compiler
optimizations, which makes the embedded application larger. Use the
debug build configuration when you want C source-level debugging.
5. Select an option in the Debug Mode section. You can debug a Blackfin
application in the following ways:
•
Instrumented debugging using a serial port—Single-stepping
and probes are faster than non-instrumented debugging, but using
a serial port requires the COM port on the Blackfin target to be
connected to the host PC, is intrusive on real-time performance,
and uses a larger amount of memory on the Blackfin target. The
LabVIEW C Code Generator adds a communication layer to the
generated C code for synchronization and data transfer. You must
remove the checkmark from the Redirect stdout to serial port
checkbox on the Advanced tab before you can select the serial
port debug option.
•
Instrumented debugging using a TCP port—Single-stepping
and probes are faster than non-instrumented debugging, but using
a TCP port requires that the Blackfin target is connected to an
Ethernet port, is intrusive on real-time performance, and uses a
larger amount of memory on the Blackfin target. The LabVIEW C
Code Generator adds a communication layer to the generated
Embedded Module for Blackfin Processors
18
ni.com
C code for synchronization and data transfer. You must place a
checkmark in the Enable lwIP TCP/IP support checkbox on the
Advanced tab before you can select the TCP port debug option.
Note You must connect the Blackfin target to the host computer with an Ethernet cable to
use lwIP TCP/IP support.
•
Non-instrumented debugging using a JTAG/EZ-KIT USB
connection—Single-stepping and probes are slower than
instrumented debugging, but using JTAG or USB does not require
a network connection.
connection to download a Blackfin application to a Blackfin target, run the application on
the Blackfin target, reset the processor, and so on, even if you use a serial port or TCP port
for debugging.
This tutorial uses the non-instrumented debug mode as shown in
Figure 13, but you can select any debug mode.
Figure 13. Configuring the Build Options
© National Instruments Corporation
19
Embedded Module for Blackfin Processors
7. Select Source Files from the Category list and select
Blackfin Tutorial.vi in the source files list. Click the blue right arrow
button, shown at left, to move the VI from the source files list to the
Top-level VI text box as shown in Figure 15.
Figure 15. Selecting the Top-Level VI for the Build Specification
© National Instruments Corporation
21
Embedded Module for Blackfin Processors
8. Click the OK button and expand the Build Specifications item in the
Project Explorer window. The build specification you just created
appears under the Blackfin target as shown in Figure 16.
Figure 16. Blackfin Build Specification in the Project Explorer Window
9. Triple-click VDK Application and rename the build specification to
Debug configurationas shown in Figure 17.
Tip You also can right-click VDK Application and select Rename from the shortcut
menu to edit the build specification name.
Figure 17. Renaming the Blackfin Build Specification
10. Select File»Save Project in the Project Explorer window to save the
project. Build specifications are saved with the project.
Embedded Module for Blackfin Processors
22
ni.com
Building, Downloading, and Running a Blackfin Application
After you develop the Blackfin VI on the host computer, you build the
Blackfin VI into a Blackfin application you can run on a Blackfin target.
generates C code from the LabVIEW block diagram using the settings you
configure.
Note Before you can build, or compile, a Blackfin VI into a Blackfin application, you
must configure the build specifications, the target settings, and the debug settings. Refer
to the Creating the ADSP-BF537 Build Specification and Configuring the Target and
Debugging Options sections for information about configuring specifications and settings.
1. Right-click Debug configuration in the Project Explorer window
and select Build from the shortcut menu to build the Blackfin VI into
a Blackfin application. LabVIEW displays the status of the building
and linking process.
2. Right-click Debug configuration again and select Debug from the
shortcut menu to deploy the application to the Blackfin target. The
application automatically runs on the Blackfin target when you select
Debug from the shortcut menu.
3. Enter a value in the threshold front panel numeric control of the
Blackfin Tutorial VI on the host computer.
4. Enter different values in the input numeric control. In Figure 18, the
front panel on the left does not exceed the threshold value. If you enter
a number greater than the threshold, the threshold exceeded? LED
lights as shown in the front panel on the right in Figure 18.
Figure 18. Increasing Input Causes Output to Exceed Threshold and Lights the LED
5. Click the Abort Execution button, shown at left, to stop the Blackfin
application.
© National Instruments Corporation
23
Embedded Module for Blackfin Processors
Debugging with Breakpoints and Probes
Complete the following steps to debug the Blackfin tutorial application
with breakpoints and probes.
1. Switch to the block diagram if it is not visible.
2. Right-click the Multiply function and select Set Breakpoint from
the shortcut menu. The breakpoint is highlighted with a red border
around the function. When you run the Blackfin application, execution
pauses just before the function executes. If you are using JTAG or
USB/EZ-KIT for debugging, LabVIEW might prompt you to halt the
processor.
3. Right-click Debug configuration in the Project Explorer window
and select Debug from the shortcut menu. LabVIEW prompts you to
save changes to the VI. LabVIEW also prompts you if you need to
rebuild or redownload the Blackfin application to the Blackfin target.
Tip LabVIEW uses default values for controls and indicators when building a Blackfin
VI into a Blackfin application. To change the initial values, enter the new values in the front
panel controls and then select Edit»Make Current Values Default to change the initial
values. You must rebuild the Blackfin application after you change the initial values of the
controls.
The Blackfin tutorial application begins running on the Blackfin target.
When you reach a breakpoint during execution, the Blackfin target
halts all operation, the application pauses, and the Pause button, shown
at left, appears red and changes to a Continue button.
Embedded Module for Blackfin Processors
24
ni.com
4. Add a probe to see the values on the wire coming into the Multiply
function.
a. Click the wire coming into the x input.
b. Click the wire coming into the y input.
A floating Probe window appears after you create each probe.
LabVIEW numbers the Probe windows automatically and displays the
same number in a glyph on the wire you click as shown in Figure 19.
Figure 19. Creating Probes
5. Enter a different value in the input numeric control.
6. Click the Continue button, shown at left, a few times to see the value
in the Probe windows change as the Blackfin application executes
additional iterations of the While Loop.
7. Click the Step Over button, shown at left, to execute a node and pause
at the next node. The node blinks when it is ready to execute.
8. Continue clicking the Step Over button to step through the rest of the
block diagram.
9. Click the Abort Execution button to stop the application.
© National Instruments Corporation
25
Embedded Module for Blackfin Processors
Where to Go from Here
National Instruments provides many resources to help you succeed with
your NI products. Use the following documentation resources as you start
exploring LabVIEW and the Embedded Module for Blackfin Processors.
•
LabVIEW Help, available by selecting Help»Search the LabVIEW
Help in LabVIEW, provides information about LabVIEW
programming, step-by-step instructions for using LabVIEW, and
reference information about LabVIEW VIs, functions, palettes,
menus, and tools. Refer to the Embedded Module for Blackfin
Processors book on the Contents tab of the LabVIEW Help for
information specific to the Embedded Module for Blackfin Processors
and Blackfin applications.
•
•
•
Context help provides brief descriptions of VIs and functions with a
link to the complete reference for a VI or function. Select Help»
Show Context Help to open the Context Help window.
Examples are available in the labview\examples\lvemb\
Blackfindirectory and can help you get started creating Blackfin
VIs.
The readme file, available by selecting Start»All Programs»
National Instruments»LabVIEW»Readme and opening
readme_BLACKFIN.html, contains known issues and last-minute
information.
•
•
•
The Getting Started with ADSP-BF537 EZ-KIT Lite manual, available
in the EZ-KIT box, familiarizes you with the hardware capabilities of
the EZ-KIT.
The ADSP-BF537 EZ-KIT Lite Evaluation System Manual, available
in the EZ-KIT box, describes the operation and configuration of the
board components and provides a schematic for reference.
The DAQ Adapter User Guide describes how to install the National
Instruments DAQ Adaptor and provides pinout information. The
NI DAQ Adaptor comes in the EZ-KIT box.
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legalfor more information about National
Instruments trademarks. Other product and company names mentioned herein are trademarks or trade
names of their respective companies. For patents covering National Instruments products, refer to the
appropriate location: Help»Patents in your software, the patents.txtfile on your CD, or
ni.com/patents.
© 2006–2007 National Instruments Corporation. All rights reserved.
371656B-01
Feb 07
|